Hpge dead layer
WebAim of the work isinvestigating the influence of the dead-layer thickness on the Broad-Energy HPGe (BEGe) detector efficiency using MCNP5 code as well as calculating the … Webof the dead layer, the Monte Carlo code MCNP has been used. The MCNP code is the most widely used for all types of particle transport, e.g., neutron, photon, and electron, based …
Hpge dead layer
Did you know?
Web1 okt. 2016 · This study presents a procedure to estimate the thickness of the inner dead-layer of n-type HPGe using MCNP5 code. First, we reduced the discrepancy in shape … WebDC Field Value Language; dc.contributor.author: 김정란-dc.creator: 김정란-dc.date.accessioned: 2016-08-25T06:08:34Z-dc.date.available: 2016-08-25T06:08:34Z …
Web1 mei 2014 · The HPGe detector was modeled using MCNP6 and Geant4, and the thickness of the dead layer of germanium crystals was estimated for an accurate simulation. The … Web12 okt. 2016 · I have a question about the dead layer properties of HPGe gamma semiconductor detectors. I found this on Wikipedia. As of 2012 HPGe detectors …
Web30 okt. 2024 · It is worth noting that the lateral dead-layer and the top dead-layer were adjusted separately and different thicknesses of these layers were expected. The … Web1 feb. 2024 · The dead layer of HPGe causes a decrease in the detection efficiency for low energy gamma rays of 100 keV or less. • The dead layer of HPGe can be …
WebThe study shows that the PHITS MC simulation program can be successfully used in obtaining efficiency calibration of HPGe detectors and determining the dead layer …
WebIn an undertaken study,9 the dead layer measurements of a standard HPGe detector were carried out with a 207Bi source. The 975keV internal conversion electrons of 207Bi were … olive oil body scrub diyWebModel 2024 : HPGe detector & 3 cylinder extended sources-. HPGe detector: Ge crystal, (dead layer), central hole and Al housing-. Extended source: high density water solution … olive oil bottle factoryWebIntroduction The dead layer thickness provided by the manufacturer increases with the aging of the HPGe detector; the increase of dead layer thickness leads to the decrease … olive oil body scrubWebcrystal has also a layer of Mylar in front of the cryostat window (0.03 mm). The effective thickness of the dead layer is not well known a cause of the existence of a transition … olive oil bottle dispenser topWebbased on data detector-source configuration with a dead layer thickness variations of 1-2 mm. It can be concluded that the dead layer thickness was 1.50 mm with a deviation of … is al-islam.org shiaWebthere is a p-type of HpGe detectors, this kind is characterized by the litium dead layer wich existe in the outer side of the detector cristal and it is increased with the passage of time (... olive oil body lotion benefitsWebDead layer thickness Dead layer exists on the surface of the entire crystal, which could be expressed as front, side, back and inner four different regions. The total thickness of … is alison certificate valuable